RoomPerfect Step 3: Measure the Room Positions

Last updated

Start Here

Guides

Resources

This is where RoomPerfect is unlike other systems. The room positions should be random, not neatly around your seat.

Jump to: Beginner Advanced

Measure around the room

Beginner

  • Move the stand to a random spot in the room and measure.
  • Vary the height, direction and angle of the mic each time, including pointing it up, down or sideways.
  • Keep the mic at least 0.5 m from walls and at least 1 m from speakers.
  • After each measurement RoomPerfect shows a Room Knowledge percentage. Keep going until it reaches about 90 to 95%.

Don’t chase 100%. Lyngdorf says that forcing it higher means placing the mic in less random spots, which biases the result.

Source: Lyngdorf’s RoomPerfect support page.

Next step

Step 4: Choose your filter and voicing

Measuring done. RoomPerfect has calculated its filters. Next, choose which to use.


Room Knowledge in more detail

Advanced

Lyngdorf doesn’t set a number of positions. The Room Knowledge figure decides when you have enough. AVForums’ walkthrough reaches about 95% with random positions, then adds two measurements close to room boundaries, which typically lifts it to about 98%.

Unlike Audyssey or Dirac, the mic shouldn’t stay at ear height for these. The point is to sample the whole room, not the seats.