No microphone connected message

  1. Check the mic cable is connected to the microphone socket and to the mic itself.
  2. Use only the Lyngdorf microphone, which runs on non-standard power.
  3. If the mic has been dropped, it may be damaged and need replacing.

Source: Lyngdorf.

Fault – No signal

  1. Unmute the volume.
  2. Check no cable is disconnected, then retry.

Source: Lyngdorf.

Fault – Signal clipping

  1. Lower the calibration volume (the unit recommends a level at the focus measurement; adjust and retry).
  2. Keep the room quiet; a loud nearby noise can corrupt the measurement.

Source: Lyngdorf.

Fault – Low signal / measurement takes forever

  1. The message appears if the low-frequency measurement runs over 5 minutes or the high-frequency over 2 minutes.
  2. Raise the calibration volume and reduce background noise, then retry.

Source: Lyngdorf.

Where do I put the mic for the focus position?

  1. Place it at the main listening seat, at head height, pointing as your head would.
  2. The system plays a tone from the left speaker and suggests a calibration volume; accept or adjust and retry.

Source: Lyngdorf.

Room Knowledge won’t climb / how many room positions?

  1. Move the mic to random, varied positions, heights and angles (point it up, down, sideways). Avoid symmetrical spots.
  2. Keep at least 0.5 m from walls, floor and ceiling, at least 1 m from speaker fronts, and about 50 cm between positions. Do not hide it behind furniture.
  3. Stop at 90% or more; about 95% is very good. Chasing 100% biases the result.

Source: Lyngdorf.

Focus or Global: which filter should I use?

  1. Focus: best for one listening seat.
  2. Global: better across the whole room.
  3. Compare with the Bypass function on the remote.

Source: Lyngdorf.

Result sounds too bright, thin or not bassy enough

  1. Do not try to edit the correction; Lyngdorf says it is neither required nor useful.
  2. Use the Voicing menu to shape tonal balance, and assign voicings per source.

Source: Lyngdorf.

Subwoofer integration / do I need to redo RoomPerfect after changes?

  1. Enter distances correctly: main speakers to the speaker front; subwoofers to the sub’s rear corner.
  2. On MP-series, run Adjust Sub so subs are aligned with each other and the speaker channels before calibrating.
  3. After any change to Output setup, distances, crossovers or sub settings, run a new RoomPerfect calibration.
  4. Back up your settings after every calibration (the manual says “ALWAYS”).
  5. SONOS TRUEPLAY

Source: ManualsLib (MP-60 manual); Lyngdorf.

Menu names and messages vary between models and software versions. If yours differ, check your own manual.